INTRODUCTION
ARCTIC AIR Packaged Air Conditioners are designed and manufactured to meet the requirements of the Pakistan severe climatic conditions and are built specifically for outdoor installations, either on ground or roof level. The Packaged Air Conditioners are ideal for warehouses, large halls, schools, mosques, or wherever the requirement is for a heavy-duty unit with a hermetic compressor.
​
CWPAC Packaged Air Conditioners are completely assembled, internally wired, charged with R22 refrigerant at the factory, tested before dispatch and ready for installation. All that is required on-site is to connect the ducting and power supply. This greatly reduces installation work and costs. They are designed for ducted applications.




Range
Available in 11 different sizes from 7.5 to 49.4 nominal TR (26.3 to 173.7 kW ) CWPAC units are designed to operate in a wide ambient temperature range from 50°F (10.0°C) to 125°F (52.0°C) and even lower if an optional head pressure control system is provided.

GENERAL FEATURES
The ARCTIC AIR Packaged Air Conditioners incorporating a high-efficiency cooling coil, heavy-duty evaporator blower and motor resulting in an extremely rugged, long life, energy-efficient, self-contained unit that will provide cooling at higher efficiency over a long and extended life. Compared to the traditional units available in the market, the ARCTIC AIR Packaged Units are very low on energy consumption.
Compressors used in the Packaged Units are hermetically sealed scroll/Reciprocating type.
-
Condenser coils are manufactured from seamless copper tubes mechanically bonded to aluminum fins to ensure optimum heat transfer.
-
The condenser fans are propeller type, directly driven by electric motors.
-
Evaporator coils are manufactured from 3/8`` (9.5 mm) OD seamless inner grooved copper tubes mechanically bonded to aluminum fins to ensure optimum heat transfer
-
CWPAC come complete, as standard, with correctly sized and piped refrigerant lines including filter drier, thermostatic expansion valve, shutoff valve and a full operating charge of R22 in each circuit
Optional Features & Accessories
-
Pressure gauges to witness the compressor operating conditions (in outdoor unit).
-
Rubber vibration isolators, to eliminate the transmission of unit’s vibration to the building.
-
Power Breaker for protection against and short circuiting.
-
Low ambient Control, to keep operating compressor discharge pressure within limits. When ambient temperature is low but unit required to operate on cooling, due to high inside temperatures.
-
Electrical Heater, for heating.